Inverter, Sunverter, UPS and Lithium Battery Repair in Shiraz

Arshid Solar’s workshop in Shiraz repairs solar and backup-power equipment: solar inverters (sunverters, hybrid and on-grid), UPS units for home, office and industry, lithium batteries and BMS — from accurate diagnosis to part replacement, load testing and re-commissioning on site.

Online repair request: send the device model, battery type and the problem on WhatsApp, or use our repair request form (Persian), and our technicians will call you.

Solar inverter repair

  • Overload, Over Current, Bus Voltage, Over Temperature, Fan and Ground Fault errors
  • Inverters that do not turn on, have no output, beep, or keep shutting down and resetting
  • Not charging the battery, not detecting PV or grid, not switching to battery or grid
  • Repair of power and control boards; replacement of fans, capacitors and faulty parts
  • Re-configuration of charge and output priorities

Sunverter repair (Growatt, Sako, MUST and other brands)

Off-grid inverters with a solar charger are the most common backup-power device in homes, shops and gardens around Shiraz. We repair Sako, Growatt, MUST, Foton and other brands and test them under load:

  • Units that will not start or shut down when a load is connected
  • Faulty MPPT section — battery not charging from PV
  • Not switching to grid or battery, unusual transformer noise, overheating
  • Burnt MOSFETs, IGBTs, capacitors and power boards; control and display board repair
  • 12 V and 24 V inverters and home sine-wave inverters

As the official Sako representative, we service Sako sunverters with original parts.

Is your inverter or sunverter faulty?

Send the model, the error code or a photo of the display; we tell you the likely cause and cost before repair.

UPS repair

  • UPS that does not turn on, has no output or beeps continuously
  • Red light, Overload or Battery errors, going to Bypass
  • Not charging the battery, not switching to battery or shutting down early
  • UPS battery replacement (12 V sealed lead-acid / gel) and conversion to lithium
  • Service of home, computer, shop, refrigerator and elevator UPS units

Lithium battery and BMS repair

  • Batteries that do not turn on, will not charge or discharge, or cut off under load
  • BMS errors and lost communication between battery and inverter (CAN and RS485)
  • 48 V / 51.2 V batteries that never reach full charge or empty too quickly
  • Cell balancing checks, faulty cell replacement and BMS repair where economical

How it works

StepWhat happens
1. Send detailsModel, error code and photos on WhatsApp
2. DiagnosisThe device is checked in our Shiraz workshop; on-site checks are also possible
3. QuoteCause and cost are announced before any repair
4. Repair & testRepair with suitable parts and a load test before delivery

Devices are accepted from other cities in Iran. See also solar panel and plant service and PLC and drive repair.